Skip to content
ALBYR Structures
Vertical extension — Issy-les-Moulineaux (92)

Vertical extension — Issy-les-Moulineaux (92)

Preliminary design

Key features

Four-storey vertical extension of an existing building

Bracing provided by an external exoskeleton

The existing structure carries vertical loads only.

ALBYR’s appointment

  • Preliminary sizing of the steel members
  • Design report
  • Preliminary load take-down

Project gallery

Surélévation - Issy Les Moulineaux (92)
Surélévation - Issy Les Moulineaux (92)

About this project

How do you add storeys to an existing four-storey building?

On this project, the bracing is provided by an external steel exoskeleton, the existing structure carrying vertical loads only. Horizontal actions — wind, seismic — are thus taken entirely outside the original building.

This split is what makes the scheme possible: an old structure can often accept additional vertical load, much more rarely the additional horizontal forces that come with extra height.

What was the appointment of ALBYR Structures?

ALBYR Structures carried out the preliminary design, for the steelwork contractor VIRY and Upfactor: preliminary sizing of the steel members, design report and preliminary load take-down.